For PeopleSoft - PeopleCode 3-tier debugging, use PSADMIN to make sure that the following items are set.
1) The appropriate PSDBGSRV Listener Port is specified in the PeopleCode Debugger section of PSADMIN.
For example: Values for config section - PeopleCode Debugger
PSDBGSRV Listener Port=9500
2) At least two PSAPPSRV processes configured to boot in the domain with the Service Timeout parameter set to 0 (zero).
The minimum requirements for PeopleCode debugging are:
- Two (2) PSAPPSRV server processes configured to boot in the domain.
- The Service Timeout value in the PSAPPSRV configuration section must be set to zero (0).
The following example shows a sample PSAPPSRV section properly configured for debugging PeopleCode:
Values for config section - PSAPPSRV
Min Instances=2
Max Instances=2
Service Timeout=0
Recycle Count=0
Allowed Consec Service Failures=0
Max Fetch Size=5000
3) Enter y for Yes at the "Enable PSDBGSRV Server Process" prompt at the end of the PSADMIN interface.
After you have specified your settings using PSADMIN the system prompts you with a series of options, such as setting up messaging server processes, enabling Jolt, and so on. When prompted to enable the PSDBGSRV, enter Y. The Developer template defaults to Y.
Subscribe to:
Post Comments (Atom)
OCI - Attach Block Volume to Windows VM
Tip: Although creating and attaching Block Storage to a Windows VM is pretty straightforward (OCI documentation is pretty good for that), th...
-
PeopleSoft Compare Reports: The compare reports are critical tools for the Fit/Gap analysis and determining the effort to re-apply/re-d...
-
Download this document - ( .doc ) or ( .pdf ) Change Assistant Introduction Change Assistant (CA) was first released in PeopleTools 8.44. C...
-
Process group is crucial in securing the processes and jobs in the system. It is possible to restrict access to certain processes within Pe...
3 comments:
Can someone please help me .. I am coding a port in the .cfg file, but when I restart the services and do an lsof display .. the debugger process is NOT listening on the port given ? can anyone help ???
PSDBGSRV 2670 hfuldvla 3u IPv4 0x300e02ec360 0t0 TCP csslu280fe:63806 (LISTEN)
- Is your app server able to restart successfully (from PSADMIN utility) after configuring PSDBGSRV?
- Did you check if the port is not being used by any other application in the box?
Hi Rakesh,
I am unable to debug using 3-tier mode. It is saying the port number is incorrect. I have used the WSL port. tried using the PIA port. is there something that i am missing. I checked the PSDBGSRV listener ports in config mgr and appsrv.cfg both are same.